Friday, November 28, 2014

BOTTOM BALANCING MODULE 2 CONTINUES

Last week the clip came off of the Powerlab 6 and blew an IGBT. I needed to charge all of the cells back up to 3 volts, so purchased a SKYRC iMAX B6 Super Mini Professional Balance Charger. So far, the charger has been working great, just charging from the unit, without having the computer interface hooked up.


BOTTOM BALANCE SET-UP


SKYRC - iMAX B6 DISPLAY

The cells are all below 3 volts and so far, I have not been able to set the iMax B6 to automatically shut off at that voltage, so have to manually shut the charge off. The cells are all reaching 3 volts and when the charge is discontinued, dropping back to 2.9 volts or so. My strategy is to get them to all fall back to around the same voltge (2.95) after they have been charged to 3 volts. Charging them will keep the cells from drifting up like they do when discharging them and I should be able to get them all to the same voltage much easier doing a charge rather than a discharge.

The temperature is supposed to get into the high 40s on Saturday and High 50s on Sunday, so will try and take this opportunity to get the Fiero in the garage. 

Thanks for visiting,

Randy

No comments: